Fujitsu
Nocria Arctic LBC error codes
Every documented code for this model family, with what it means and whether it is safe to act on yourself.
6 models in this family
- AWYZ14LBC
- AWYZ18LBC
- AWYZ24LBC
- AOYZ14LBC
- AOYZ18LBC
- AOYZ24LBC
27 codes
- live-maintenance-lamp-blink-filter-movement-stopped Automatic filter-cleaning movement stopped Warning
- live-maintenance-lamp-blink-filters-missing Air filters missing during automatic cleaning Warning
- live-operation-and-timer-lamps-blink-fault Operation and timer lamps blinking together Fault
- live-operation-lamp-2-blinks-timer-lamp-2-blinks Room-temperature sensor fault Fault
- live-operation-lamp-2-blinks-timer-lamp-3-blinks Indoor heat-exchanger temperature sensor fault Fault
- live-operation-lamp-3-blinks-timer-lamp-2-blinks Discharge-temperature sensor fault Fault
- live-operation-lamp-3-blinks-timer-lamp-3-blinks Outdoor heat-exchanger temperature sensor fault Fault
- live-operation-lamp-3-blinks-timer-lamp-4-blinks Outdoor-temperature sensor fault Fault
- live-operation-lamp-4-blinks-timer-lamp-2-blinks MANUAL AUTO switch fault Fault
- live-operation-lamp-4-blinks-timer-lamp-3-blinks Main relay fault Fault
- live-operation-lamp-4-blinks-timer-lamp-4-blinks Power-supply frequency detection fault Fault
- live-operation-lamp-5-blinks-timer-lamp-2-blinks Inverter power module (IPM) protection Fault
- live-operation-lamp-5-blinks-timer-lamp-3-blinks Current sensor fault Fault
- live-operation-lamp-5-blinks-timer-lamp-5-blinks Compressor rotor-position detection fault Fault
- live-operation-lamp-5-blinks-timer-lamp-6-blinks Outdoor fan motor fault Fault
- live-operation-lamp-6-blinks-timer-lamp-2-blinks Indoor fan motor locked Fault
- live-operation-lamp-6-blinks-timer-lamp-3-blinks Indoor fan speed fault Fault
- live-operation-lamp-7-blinks-timer-lamp-2-blinks Discharge-temperature fault Fault
- live-operation-lamp-7-blinks-timer-lamp-3-blinks High-pressure protection in cooling Fault
- live-operation-lamp-8-blinks-timer-lamp-2-blinks PFC circuit fault Fault
- live-operation-lamp-8-blinks-timer-lamp-3-blinks Active filter fault Fault
- live-operation-lamp-blink-defrost Automatic defrost indication Informational
- live-operation-lamp-off-timer-lamp-2-blinks Serial communication fault at start-up (indoor side) Fault
- live-operation-lamp-off-timer-lamp-3-blinks Serial communication fault during operation (indoor side) Fault
- live-operation-lamp-off-timer-lamp-4-blinks Serial communication fault at start-up (outdoor side) Fault
- live-operation-lamp-off-timer-lamp-5-blinks Serial communication fault during operation (outdoor side) Fault
- live-timer-lamp-blink-power-failure Timer reset after power failure Warning
No code matches that. Clear the filter to see all 27.